Introduction ______________________________________________________________________
The 830S and 850S series full-circle rotary sprinklers are designed
specifically for golf course applications.
Manufactured from durable, high-strength engineering plastic and
stainless-steel components, these sprinklers incorporate many innovative
and time-proven features for lasting, maintenance-free operation.
Prior to installing the sprinkler, read through the recommended installation
and start-up procedures. Please observe all
WARNINGS and CAUTIONS
when installing and operating this equipment.
Features _______________________________________________________________________________
Specifications and Performance/Application Data _______________________________________
830S Series
Radius: 5589' (16.827.1 m)
Flow Rate: 13.645.3 GPM (51.4171.5 l/mn)
Trajectory: 25°
Arc: Full Circle
Recommended Operating Pressure: 50100 PSI
(3.56.9 Bar)
Minimum Pressure: 40 PSI (2.8 Bar)
Maximum Pressure: 150 PSI (10.3 Bar)
Precipitation Rate:
Minimum: 0.46"/hr (11.7 mm/hr)
Maximum: 0.63"/hr (16 mm/hr)
Body Height: 10" (25.4 cm)
Pop-Up Height: 3" (7.6 cm)
1" NPT, BSP or ACME Female Thread Inlet
Spike Guard
TM
Solenoid:
24 V a.c., 50/60 Hz
Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)
60 Hz, 0.12 Amps (2.9 VA)
Holding Current: 50 Hz, 0.15 Amps (3.6 VA)
60 Hz, 0.10 Amps (2.4 VA)
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic model checks up to 37' (11.3 m) of elevation.
Nozzle Variations: See chart on page 2.
850S Series
Radius: 55'100' (16.7 m30.4 m)
Flow Rate: 13.961.7 GPM (52.6233.5 l/mn)
Trajectory: 25°
Arc: Full Circle
Recommended Operating Pressure: 50100 PSI (3.56.9 Bar)
Minimum Pressure: 40 PSI (2.8 Bar)
Maximum Pressure: 150 PSI (10.3 Bar)
Precipitation Rate:
Minimum: 0.50"/hr (12.7 mm/hr)
Maximum: 0.72"/hr (18.3 mm/hr)
Body Height: 11" (27.9 cm)
Pop-Up Height: 3" (7.6 cm)
1.5" NPT, BSP or ACME Female Thread Inlet
Spike Guard
TM
Solenoid:
24 V a.c., 50/60 Hz
Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)
60 Hz, 0.12 Amps (2.9 VA)
Holding Current: 50 Hz, 0.15 Amps (3.6 VA)
60 Hz, 0.10 Amps (2.4 VA)
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic model checks up to 37' (11.3 m) of elevation.
Nozzle Variations: See chart on page 2.
830S Electric Valve-In-Head 850S Electric Valve-In-Head
Full 3" (7.6 cm) pop-up clears tall grasses
Nozzles color-coded by radius and gallonage
Cap serves as an effluent water indicator
Variable stator
Standard pressure regulation settings of 50 psi (3.4 bar),
65 psi (4.5 bar), 80 psi (5.5 bar) or 100 PSI (6.9 bar) to
ensure consistently accurate nozzle performance
regardless of elevation
Three body activation types available: Electric VIH,
Normally Open Hydraulic VIH, and Check-O-Matic
Three body thread types available: NPT, BSP and ACME
Manual control at the sprinkler, On-Off-Auto (Electric VIH only)
Bowl-vented discharge (atmospheric) minimizes the
differential pressure required for regulation and ensures
positive valve closure (Electric VIH only)
All internal components serviceable from the top of the
sprinkler
Large selection of color-coded nozzles available
Durable plastic and stainless-steel construction
Spike-Guard
TM
solenoid for superior surge protection
1
A U T O
O
N
830S and 850S Series Rotary Sprinklers
Installation & Service Instructions
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - 850S Series

Introduction ______________________________________________________________________The 830S and 850S series full-circle rotary sprinklers are designed

Strany 2 - Sprinkler Application Data

26626.2 31.5 34.136.574 808331.8 73 32.7 75 36.139.5798341.644.2838748.151.68589850S Series Sprinkler Performance Data830S Series Sprinkler Performanc

Strany 3 - Constructing Swing Joints

Installation Procedure ___________________________________________________To assure maximum performance from your 800S series sprinklers, read these i

Strany 4 - Pilot Valve

System Start Up _________________________________________________________The following is a recommended procedure that will protect system components

Strany 5 - Main Valve

Sprinkler AssemblyPROBLEM POSSIBLE CAUSE – CORRECTIVE ACTIONSPRINKLER WON'T ROTATE (a) Debris wedged between stator and turbine. – Remove obstr

Strany 6 - Servicing Sprinkler Mechanism

VALVE WON'T OPEN (a) Plugged controller discharge line or discharge port in pilot valve. (Hydraulic) – Verify by checking for discharge at discha

Strany 7 - Servicing Main Valve

Servicing Main Valve1. See WARNING above. To remove valve assembly, squeezesnap ring ears together with snap ring pliers (P/N 995-100) andremove snap

Strany 8 - Servicing Pilot Valve

Servicing Pilot ValveNote: Refer to Figure 7 for the following procedure.1. Make sure that the water supply to sprinkler ispositively shut off and any