ECXTRA Features
Easily expandable to 10 Zones (Indoor
model) or 12 Zones (Outdoor Model) with
2-zone Plug-in Modules
Snap-in Wire Connectors
Compatible with Optional Scheduling
Software Package
3 Independent Watering Programs with:
- Calendar, Interval and Odd/Even Days
- Selective Day Exclusion
- 1-minute to 4-hour Zone Run Time
- 4 Start Times
Seasonal Run Time Adjust
Rain Delay
Compatible with Normally Closed or
Normally Open Rain Sensors
Automatic 24 VAC Circuit Protection
Program Memory Backup without Battery
Programmable Pump Start
B
CA
MANUAL
START
ON
NEXT
OFF
MANUAL
START
ON
NEXT
OFF
Sprinkler Timer with
Computer Programming
Option
User’s Guide
INDOOR MODEL
OUTDOOR MODEL
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - User’s Guide

ECXTRA Features• Easily expandable to 10 Zones (Indoor model) or 12 Zones (Outdoor Model) with 2-zone Plug-in Modules• Snap-in Wire Connectors• Compat

Strany 2

  Connecting a Pump Start RelayCAUTION: To prevent timer damage, ensure the 24 VAC pump relay current draw does not exceed 0.30 Amps. Do not connect t

Strany 3 - Table of Contents

  Outdoor Model Installation1. Remove the lower housing cover (A) by pulling outward on the handle.2. Remove the two phillips screws from the trans

Strany 4 -   Timer Components

  Installing the Cabinet1. For safe, reliable operation, select an installation site which will provide the following conditions: • Protection from

Strany 5

11  Connecting the Valves1. Route the valve wires or wire cable from the valves, into the timer cabinet. Note: The snap-in wire connectors accept 14

Strany 6

  Connecting a Pump Start RelayCAUTION: To prevent timer damage, ensure the relay current draw does not exceed 0.30 Amps. Do not connect the timer dir

Strany 7

 Connecting the Power Source (cont.) Connecting (optional) Rain Sensor A rain sensor is a remote sensing device that can be connected directly to your

Strany 8 - Timer Installation

  Getting Started Automatic Sprinkler System BasicsThe three main operating components of every auto-matic sprinkler system are the timer, control val

Strany 9

  Watering Schedule BasicsA watering schedule consists of three basic instructions: • What days to water –called watering days • When to water – call

Strany 10 - Connecting a Pump Start Relay

16  Watering Program DetailsThis section covers in detail each of the three parts of a watering program – watering days, program start times and zone

Strany 11 - Outdoor Model Installation

Selecting Program Start TimesA program start time is the time of day you select to begin an automatic program watering cycle. It is important to reme

Strany 13 - Connecting the Valves

18Note: You can use your personal computer and the Toro Scheduling Advisor interactive software to guide you through the complete watering schedule pr

Strany 14 -  Connecting the Power Source

19SUMOTU WE TH FR SA SU MO TU WE TH FR SA SU MO TU WE TH FR SA MOSU TU WE TH FR SA SU MO TU WE TH FR SA SU MO TU WE TH FR SA 12 3 4 5 6 7 1 2 3 4 5

Strany 15 - PROGRAMS

20SUMOTU WE TH FR SA SU MO TU WE TH FR SA SU MO TU WE TH FR SA MOSU TU WE TH FR SA SU MO TU WE TH FR SA SU MO TU WE TH FR SA 12 3 4 5 6 7 1 2 3 4 5

Strany 16 - Getting Started

About the Watering Program MemoryOnce programmed, the ECXTRA memory will be retained for several years without power. Only the cur-rent time and date

Strany 17 - Watering Schedule Basics

22Note: For each program, you can select Calendar, Inter-val Odd, Even or Off. To set a Calendar schedule, con-tinue here. To set an Interval schedule

Strany 18 - Watering Program Details

23Setting an Interval Schedule Turn the control dial to the watering days position. Check the programs switch setting. If necessary, reposition the

Strany 19 -  position

Setting an Odd or Even Schedule  Turn the control dial to the watering days position. Check the programs switch setting. If necessary, reposition t

Strany 20 - Guidelines for Watering

Using the Day Exclusion Feature A Calendar watering day schedule is used to select spe-cific days of the week to water. However, if an Interval or Odd

Strany 21 - PROGRAM C

Turning Off a ProgramNote: Turning off a program does not alter or erase a preset watering day schedule. Selecting Off simply places the program on ho

Strany 22

Turn the control dial to the program start time position. Check the programs switch setting. If necessary, reposition the switch to select the desi

Strany 23 - Programming the Timer

  Table of Contents  Timer Components ... 2-5  Timer Installation   n Indoor Model Installation ...

Strany 24

PGM A1 2 3 4 5 63 53 5943521425 Turn the control dial to the set zone times position. Check the programs switch setting. If necessary, repositio

Strany 25

The Special Functions dial position provides optional control features specifically for pump system operation.Pump/Master Valve control circuit opera

Strany 26

The ECXTRA timer has three modes of operation: Auto-matic, Manual and Off. In the Automatic mode the timer tracks the time and day and operates the au

Strany 27

31Manual operation enables the automatic watering pro-grams or selected zones assigned to the program to be started manually. During operation, tempor

Strany 28 - run position

The following watering control features enable you to fur-ther control the watering program during operation.All watering control features apply to wa

Strany 29 - Setting Program Start Times

33This feature enables all watering operations to be delayed from 1 to 7 days. For example, rain is forecast in your area for the next two days. Inste

Strany 30 - Setting Zone Run Times

Changes in season and temperature generally require a change in zone run time to maintain a healthy landscape and conserve water. The Season Adjust f

Strany 31 - Pump Control

When the control dial is turned to the off position, the timer immediately shuts off any watering operation cur-rently in progress. Leaving the contro

Strany 32 - Timer Operation

Once programmed, the ECXTRA memory will be retained for several years with or without power. Only the current time and date information will be lost

Strany 33 - Manual Operation

The ECXTRA features built-in circuit protection to help prevent damage to the timer caused by excessive current draw on the zone and/or pump/master va

Strany 34 - Watering Control Features

  Timer ComponentsTimer Components 2SENSOR24 VACMANUALSTARTONNEXTOFFB F

Strany 35 - Using the Rain Delay Feature

38If you are having a problem with the timer, check the following symptoms, possible causes and remedies. If the problem cannot be resolved, or you w

Strany 36

Cabinet Dimensions: Indoor Model 7.5” W x 6.25” H x 2” D (19cm W x 15.9cm H x 5cm D)Outdoor Model 13.25” W x 9” H x 3.5” D (33.7cm W x 22.9cm H x 9

Strany 37 - Turning Off the ECXTRA

40Master Valve An automatic or manual control valve located between the irrigation water source and the sprinkler system valves and/or backflow preven

Strany 38 - Service and Specifications

Season AdjustSeason Adjust enables the run time of all zones to be adjusted up or down simultaneously in 10% increments from 10% to 200%. Any increase

Strany 39 - Adding a Zone Module

 WarrantyThe Toro Promise — Limited One-Year WarrantyThe Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them,

Strany 40 - Troubleshooting

Timer Components The following are brief descriptions of the timer components and display elements. Each of these items will be explained in further

Strany 41 - Specifications

Timer Components 3 - Control Dial Positions (continued) season adjust – Enables the run time of all stations in a program to be simultaneously inc

Strany 42

5BCAMANUALSTARTONNEXTOFFMANUALSTARTONNEXTOFFPump/MV24VACCOMTimer Components

Strany 43

  Timer InstallationNote: The ECXTRA indoor timer is not weather resis-tant and must be installed indoors or in a protected area.    Indoor Model Inst

Strany 44 - Electromagnetic Compatibility

  Connecting the Valves1. Route the valve control wires between the valves and the timer. Note: The snap-in wire connectors accept 14–18 gauge (2mm2